APC Smart-UPS 1000VA Tower LCD 230V (SMC1000IC )

Batteries & Runtime

Run Time : View Runtime Graph
Efficiency : View Efficiency Graph

Front View :

1. Display 2. Bezel
3. Battery 4. Internal battery connector

Rear View :

1. APC™ SmartConnect port 2. Serial port
3. USB Port 4. Chassis ground connection screw
5. Smart Slot 6. Output circuit breaker/overload protection
7. Controlled outlet group 8. Outlets
9. UPS input 10. Battery connector (located on the front panel of rack-mount models)
11. Input circuit breaker
Manageability
  • USB connectivity: Provides management of the UPS via a USB port (not available on all models).
  • Serial connectivity: Provides management of the UPS via a serial port.
  • Network manageable: Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
  • LED status indicators: Quickly understand unit and power status with visual indicators.
  • Audible alarms: Provides notification of changing utility power and UPS conditions.
Availability
  • Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.
  • Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
Serviceability
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Resettable circuit breakers: Enables a quick recovery from overload events.
  • Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
  • User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Provided equipment : Cat 5 Ethernet cable, Installation guide, USB cable
Additional specification : Cloud-enabled monitoring
Performance multiplier : 1
Number of tare power : 30W
Number of power module free slots : 0
Number of power module filled slots : 0
Redundant : No
Size UPS version : Internetworking, Server, Telecom
UPS Size : S
Value multiplier : 1
Colour : Black
Depth : 43.9 cm
Height : 21.9 cm
Mounting location : Front
Mounting preference : No preference
Net weight : 19.4 Kg
Mounting mode : Not rack-mountable
Two post mountable : 0
USB compatible : No
Width : 17.1 cm
Network frequency : 50/60 Hz +/- 3 Hz auto-sensing
Plug standard : IEC 320 C14
Input voltage limits : 151 - 302 V adjustable, 160 - 286 V
Input volt other : 220 V, 240 V
Input voltage : 230 V
Rated power in W : 700 W
Maximum configurable power in W : 700 W
Harmonic distortion : Less than 5%
Output frequency : 50/60 Hz +/- 3 Hz sync to mains
Output volt other : 220 V, 240 V
UPS type : Line interactive
Wave type : Sine wave
Nb of power socket outlets : 8 IEC 320 C13, 2 IEC Jumpers
Curve equation : Efficiency
Curve fixed loss : 0.0104
Curve load maximum : 100.00%
Curve load minimum : 2.00%
Curve proportional loss : 0
Curve square loss : 0.0024
Curve X-axis maximum : 100.00%
Curve test cond ID : Curve fit of data measured in accordance with the ENERGY STAR Test Methodfor Uninterruptible Power Supplies. All measurements taken in normal mode( s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output.
Curve X-axis minimum : 0.00%
Curve X-axis title : Load
Curve X-axis units : Percentage
Curve Y-axis maximum : 100.00%
Curve Y-axis minimum : 50.00%
Curve Y-axis title : Efficiency
Curve Y-axis units : Percentage
Graph display : 1
Output voltage : 230 V
Maximum configurable power in VA : 1000 VA
Rated power in VA : 1000 VA
Transfer time : 6 ms typical: 10 ms maximum
Ambient air temperature for operation : 0 - 40°C
Relative humidity : 0 - 95%
Operating altitude : 0 - 10000 ft
Ambient air temperature for storage : -15 - 45°C
Storage Relative Humidity : 0 - 95%
Storage altitude : 0.00 - 15240.00 M
Acoustic level : 41 dBA
Heat dissipation : 100 Btu/H
Show note OP temperature : No
Battery type : Lead-acid battery
Number of battery filled slots : 0
Number of battery free slots : 0
Battery recharge time : 3H
Number of battery replacement quantity : 1
Additional information : Configurable for 220 : 230 or 240 nominal output voltage
Liquid value : 0
Battery curve : Z
Battery charger power : 88 W rated
Battery power in VAH : 264 VAh runtime
Battery life : 3 - 5 Year(S)
Extended runtime : 0
Free slots : 1
Control panel : Multifunction LCD status and control console
Alarm : Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency power off : Optional
Package 1 Weight : 22.77 Kg
Package 1 Height : 37.6 cm
Package 1 width : 32.8 cm
Package 1 Length : 59.5 cm
Number of Units in Package 3 : 12
Warranty : 3 years repair or replace (excluding battery) and 2 years for battery