Batteries & Runtime
Run Time : | View Runtime Graph |
Efficiency : | View Efficiency Graph |
APC Back-UPS 750VA Tower 230V - BX750MI
Automatic Voltage Regulation (AVR)
Automatic Voltage Regulation boosts/trims the AC voltage when it drops/exceeds levels. This allows the equipment plugged into the unit to operate during low/high voltage conditions, conserving the battery power in the event of a power cut. The Back-UPS will switch to battery power if the input voltage level becomes too low/high for the Automatic Voltage Regulation to compensate, or if the AC power is distorted.
PowerChute Personal Edition Software
To install PowerChute Personal Edition (PCPE) software, connect a USB cable to the data port on the UPS and the other end to a computer with access to the web. On the computer, go to www.apc.com/tools/download. Select “Software Upgrades - PowerChute Personal Edition” in the “Filter by Software/Firmware” drop down menu. Select the appropriate operating system. Follow directions to download the software.
Quick Mute
The Back-UPS is able to temporarily mute user correctable audible alarms such as On Battery. During such audible alarms, a short press of the POWER button will temporarily mute the audible alarm until the condition has been reset. A short double beep will confirm that Quick Mute has been activated. Pressing the POWER button for more than 2 seconds will turn off the UPS. Other critical events such as Battery replacement and Charger notification can not be temporarily muted. The unit in these cases must be turned off.
Network frequency : | 50/60 Hz +/- 5 Hz auto-sensing |
Plug standard : | IEC 60320 C14 |
Input voltage limits : | 140 to 300 V |
Input voltage : | 230 V |
Rated power in Watt : | 410 W |
Maximum configurable power in Watt : | 410 W |
Output frequency : | 50/60 Hz +/- 1 Hz sync to mains |
UPS type Standby : | Wave type Stepped approximation to a sinewave |
Nb of power socket outlets : | 4 IEC 60320 C13 |
Output voltage : | 230 V |
Ambient air temperature for operation : | 0 to 40 °C |
Relative humidity : | 0 to 95 % non-condensing |
Operating altitude : | 0 to 3000 ft |
Ambient air temperature for storage : | -15 to 40°C |
Storage altitude : | 0.00 to 914.40 M |
Acoustic level : | 40 dBA |
Battery type : | Lead-acid battery |
Battery recharge time : | 8 H |
Control panel : | LED Status display with on line : on battery |
Alarm : | Alarm when on battery : distinctive low battery alarm |
Cable length : | 1.22 M |
Dimension (H x W x D) : | 16 x 12 x 35.5 cm |
Net weight : | 5.4 Kg |
Warranty : | 2 years repair or replace |